RUiXU
RUiXU RX-LFP48100 19″ Server Rack 3U Battery UL1973 Certified UL9540 Pending
In stockLTL freight delivery
$1,059.00
Choose your delivery ZIP
Delivery dates, freight and pickup options are based on your ZIP code.
Image 1 of 6
$1,099.00
In stock
Questions? Call (727) 761-7772
SKU RX-LFP48100-H
The self-heating 48V server rack battery is designed for usage in cold weather! Can safely charge at temperatures as low as -20°C (-4°F) by a standard charger or solar charger. The heated pads draw power from the charger itself.
Support up to 32 units in parallel, scale from 5 kWh to 160 kWh configuration without external controller.
3U (133mm) standard height design
Use DIP address to set the RS485 baud rate and inverter protocol choosing
Comes with battery interconnection Amphenol connectors.
Details Rated voltage: 51.2V Max. voltage range: 44.8~57.6V, Shipping voltage>51.2V Charge voltage: 56.0V Float charge voltage: 54.6V Low voltage cut-off: 44.8V Nominal energy: 5.12KWh Usable energy: 4.92kWh Nominal capacity: 100Ah Dimensions: 482*133.5*460mm (18.9*5.2*18.1 inch) Weight: ~50kg (110lbs) Standard charge current: ≤50A Max. charge current: 70A Standard discharge current: ≤50A Max. discharge current: 100A (initial temp. ≤35℃ [95°F]) Peak discharge current: 101~119A@5mins | 120~150A@5S Communication: RS485 /CAN Max parallel number: 32pcs Operation temperature 1 Charge: 0~50℃ (32~122°F) Discharge: -20~50℃ (-4~122°F) Storage temperature: 0℃<T<30℃ (32°F<T<86°F)<6 months | -10℃<T<45℃ (14°F<T<113°F)<3 months Recommended environment: 15~35℃ (59~95°F), 5~75%RH Start heating: When the Minimum Cell temperature is between -25°C and 5°C (-13°F and 41°F), the battery is connected to the charger or inverter and the charging current is ≥ 0.05C*N, start heating. End heating: When the Minimum Cell temperature is above 12°C (53.6°F), end heating.
(1) The optimum operating temperature range is from 15°C to 30°C (15°F to 86°F). Frequent exposure to the harsh temperatures may worsen the performance of the battery pack and cycle life.
Modular
Support up to 32 units in parallel, scale from 5 kWh to 160 kWh configuration without external controller.
Inverter Protocol Choosing
Use DIP address to set the RS485 baud rate and inverter protocol choosing
Communications
Canbus: Victron, SMA, Studer Innotec, Sofar, Solark, Solis, Goodwe, Deye, Growatt, SAJ, LUXPOWER, Megarevo, INVT, Sermatec, TBB, MUST, Sunsynk, Schneider RS485: MPP, Voltronic, RCT, Alpha outback
Standard Included
(1) RUiXU 48V Server Rack battery (RX-LFP48100-H) (1) RS485 Communication Cable (1) Ground Cable (1) Set of Parallel 4AWG Cables per battery
SKU:
RX-LFP48100-H
| Capacity | Not listed |
|---|---|
| Nominal voltage | Not listed |
| Chemistry | LiFePO4 |
| Warranty | Not listed |
| Certifications | UL 1973 |
| Dimensions | 24 × 21 × 13 in |
| Weight | 110 lb |
| Brand | RUiXU |
|---|---|
| SKU | RX-LFP48100-H |